TeSys GV mounting adapter plate, for mounting a motor circuit breakers GV2 and a contactor LC1D09-D25. Item delivered with a GV1G02 flexible connection. Sold in lots of 1 unit. Green Premium compliant (RoHS/REACh)
Blok ogranicznika prądowego TeSys GV do wyłączników silnikowych GV2L/LE/P/ME/RT. Zwiększa zdolność wyłącznika do wytrzymania prądu zwarciowego z 50 kA do 100/130 kA przy 400 V. Do montażu na wyłączniku silnikowym GV2. Zgodny z dyrektywą RoHS/REACh
For use with screw clamp terminal devices, it is composed of 2 tap-off outlets for the connection of 2 devices with a pitch of 45mm. To be supplied by a terminal block GV1G09 or GV2G05 (to be ordered separately)
For use with screw clamp terminal devices, it is composed of 4 tap-off outlets for the connection of 4 devices with a pitch of 45mm. To be supplied by a terminal block GV1G09 or GV2G05 (to be ordered separately)
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers. For use with screw clamp terminal devices, it is composed of 2 tap-off outlets for the paralleling of 2 devices with a pitch of 72mm. The...
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers. For use with screw clamp terminal devices, it is composed of 4 tap-off outlets for the paralleling of 2 devices with a pitch of 72mm. The...
Akcesorium TeSys GV, blok łączeniowy do montażu układu rozruchowego. Do połączenia między wyłącznikiem silnikowym GV2 lub rozłącznikiem bezpiecznikowym LS1D32 a stycznikiem LC1D09-D38. Do stosowania, gdy układ jest montowany bezpośrednio na szynie DIN. Zgodność z Green Premium (RoHS/REACh...
TeSys GV accessory, mounting adapter plate for motor circuit breakers GV2. For mounting a GV2 on panel by screw fixing. Sold in lots of 10 units. Green Premium compliant (RoHS/REACh)
Listwa zaciskowa TeSys GV, 3 fazy, 63A/690V, do zasilania zestawów szyn zbiorczych GV2G. Do montażu urządzeń połączonych zestawami szyn zbiorczych, na tej samej szynie DIN i podłączonych jednym z wyjść szynowych. Może być wyposażony w ogranicznik prą du GV1L3 dla wszystkich równoległych...
Blok styków pomocniczych TeSys GV do wyłączników silnikowych GV2 i GV3. Styk sygnalizacji błędu 1NO + bezzwłoczny styk pomocniczy 1NC. Styk pomocniczy bezzwłoczny o obciążalności do 6A/690V AC i 6A/240V DC. Styk sygnalizacji błędu przystosowany jest do pracy przy napięciu do 2A/240V AC...
TeSys GV auxiliary contact block, 1NO fault signalling contact and 1NO instantaneous auxiliary contact, for motor circuit breakers GV2 and GV3. Instantaneous auxiliary contact rated for AC operation up to 6A/690V and DC operation up to 6A/240V DC, fault signalling contact rated for AC operation up to...
TeSys GV auxiliary contact block, instantaneous auxiliary contacts 1NO+1NC, for motor circuit breakers GV2 and GV3. For AC operation up to 2A/240V and DC operation up to 1A/60V DC. To be installed on front side of the circuit breaker, 1 block mounting maximum, connection by screw clamp terminals. Sold...
TeSys GV auxiliary contact block, instantaneous auxiliary contacts 1NO+1NC, for motor circuit breakers GV2 and GV3. For AC operation up to 6A/690V and DC operation up to 6A/240V DC. To be installed on left-hand LH side of the circuit breaker, 2 blocks mounting possible, connection by screw clamp terminals...
TeSys GV electrical trip, MX shunt release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of...
Wyzwalacz elektryczny TeSys GV, wyzwalacz wzrostowy MX, 220-240V AC 50Hz, do wyłączników silnikowych GV2, GV3. Wyzwala wyłącznik, gdy napięcie sterujące jest podawane w granicach 0,7-1,1 Uc z czasem trwania impulsu większym niż 20 ms lub utrzymywanym sygnałem. Do montażu po prawej stronie...
TeSys GV electrical trip, MX shunt release, 220-240V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker...
Wyzwalacz elektryczny TeSys GV, wyzwalacz wzrostowy MX, 380-400V AC 50Hz / 440V AC 60Hz, do wyłączników silnikowych GV2, GV3. Wyzwala wyłącznik, gdy napięcie sterujące jest podawane w granicach 0,7-1,1 Uc z czasem trwania impulsu większym niż 20 ms lub utrzymywanym sygnałem. Do montażu po...