Open switch-disconnectors, Switch-disconnector, Number of poles 3 pole, Rated current = rated uninterrupted current 800 A, Protective function without protection, Standard/Approval IEC, Installation type Withdrawable
Accessories, Undervoltage release, Cannot be combined with a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control voltage Us...
Accessories, Horizontal and vertical connections, long, This connection kit comes with T-shaped adapters for the main terminals; these adapters can be used either as horizontal or vertical connectors., Each set contains the connections for top and bottom. 3 pole = 6 off; 4 pole = 8 off, Rear universal...
Accessories, Horizontal and vertical connections, This connection kit comes with T-shaped adapters for the main terminals; these adapters can be used either as horizontal or vertical connectors., Each set contains the connections for top and bottom. 3 pole = 6 off; 4 pole = 8 off, Rear universal connection...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching...
Accessories, closing release, Can be combined with a shunt release and an undervoltage release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control...
Accessories, closing release, Can be combined with a shunt release and an undervoltage release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control...
Accessories, Shutter, When the breaker is withdrawn from its connected position, the shutters automatically cover the cassette’s live main terminals., Installation type Withdrawable, Pole 3, For use with IZMX-CAS163…, for withdrawable unit
Accessories, Control circuit terminal units for fixed mounting, 4-point control circuit terminals, 2 units, Installation type Fixed, For use with IZMX16…, INX16…, IZMX40…, INX40…
Accessories, Control circuit terminal units for fixed mounting, 4-point control circuit terminals, 30 units, Installation type Fixed, For use with IZMX16…, INX16…, IZMX40…, INX40…
Accessories, Mechanical interlock, Type 32, for 3 circuit-breakers: Two normal incoming units (A, C) and one coupling (B). Any one or two switches can be closed at the same time. Three cable kits are required in addition, Installation type Withdrawable, For use with IZMX16…W, INX16…W
Accessories, Mechanical interlock, fixed mounting, Type 32, For 3 circuit-breakers with the same or different frame size: interlock: 2 against 1 / max. 2 ON. Any one or two circuit-breakers can be closed at the same time. In addition, three IZMX-MIL-CAB… cable kits are required. Select the appropriate...
Accessories, Mechanical interlock, Type 31 + 33, for 3 circuit-breakers: Three incoming units (A, B, C), normal or emergency network. Only one of the three switches can be switched on at any one time. Three cable kits are required in addition., Installation type Withdrawable, For use with IZMX16…W...
Accessories, Mechanical interlock, fixed mounting, Type 33, For 3 circuit-breakers with the same or different frame size: interlock: A, C against B. When B is off, A and C can be switched on. B can be switched on only when A and C are OFF. In addition, two IZMX-MIL-CAB… cable kits with the desired...
Accessories, Mechanical interlock, Type 2, for 2 circuit-breakers: A normal power supply (A) and an emergency network supply (B). 1 set of cables also required in addition., Installation type Withdrawable, For use with IZMX16…W, INX16…W
Accessories, Mechanical interlock, fixed mounting, Type 2, For 2 circuit-breakers with the same or different frame size: interlock: A against B. In addition, an IZMX-MIL-CAB… cable kit with the desired length is required. Select the appropriate part no. for each circuit-breaker., Installation type...
Accessories, Bowden cables, The description of the mechanical interlock requires a specific number of Bowden cable kits., One set contains two cables., 3050 mm long, For use with IZMX-MIL...C-F..., IZMX-MIL...C-W..., Bowden cables