Circuit-breaker IZMX40 ( Air circuit-breakers/switch-disconnectors), 4 pole, Current Range: Up to 4000 A, Rated current = rated uninterrupted current( In = Iu): 2500 A, up to 440 V 50/60 Hz( Icu): 66 kA, up to 440 V 50/60 Hz( Ics): 66 kA, Overload release, min.( Ir): 1000 A, Overload release, max.( Ir): 2500 A, Installation type: Fixed, Standard/Approval: IEC, Protective function: P measurement
Accessories, Undervoltage release, Cannot be combined with a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control voltage Us...
Accessories, Horizontal and vertical connections, Cu bars can be connected directly to the circuit-breaker"s flanged connections., This connector kit includes T-shaped adapters for all main terminals. These adapters can be mounted horizontally or vertically on circuit-breakers with ratings of up to 3,200...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching...
Accessories, closing release, Can be combined with a shunt release and an undervoltage release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control...
Accessories, closing release, Can be combined with a shunt release and an undervoltage release., Retrofitting kit, Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control...
Accessories, Control circuit terminal units for fixed mounting, 4-point control circuit terminals, 2 units, Installation type Fixed, For use with IZMX16…, INX16…, IZMX40…, INX40…
Accessories, Control circuit terminal units for fixed mounting, 4-point control circuit terminals, 30 units, Installation type Fixed, For use with IZMX16…, INX16…, IZMX40…, INX40…
Accessories, Locking ON/OFF buttons, The circuit-breaker"s ON/OFF buttons can be locked together by using the interlock. It is also possible to lock only the ON or the OFF button by using a padlock., This means that it will no longer be possible to actuate the circuit-breaker locally., The optional remote...
Accessories, Locking ON/OFF buttons, The circuit-breaker"s ON/OFF buttons can be locked together by using the interlock. It is also possible to lock only the ON or the OFF button by using a padlock., This means that it will no longer be possible to actuate the circuit-breaker locally., If the OFF button...
Accessories, Locking ON/OFF buttons, The circuit-breaker"s ON/OFF buttons can be locked together by using the interlock. It is also possible to lock only the ON or the OFF button by using a padlock., This means that it will no longer be possible to actuate the circuit-breaker locally., The optional remote...
Accessories, Mechanical interlock, fixed mounting, Type 32, For 3 circuit-breakers with the same or different frame size: interlock: 2 against 1 / max. 2 ON. Any one or two circuit-breakers can be closed at the same time. In addition, three IZMX-MIL-CAB… cable kits are required. Select the appropriate...
Accessories, Mechanical interlock, fixed mounting, Type 2, For 2 circuit-breakers with the same or different frame size: interlock: A against B. In addition, an IZMX-MIL-CAB… cable kit with the desired length is required. Select the appropriate part no. for each circuit-breaker., Installation type...
Accessories, Bowden cables, The description of the mechanical interlock requires a specific number of Bowden cable kits., One set contains two cables., 3050 mm long, For use with IZMX-MIL...C-F..., IZMX-MIL...C-W..., Bowden cables
Accessories, Bowden cables, The description of the mechanical interlock requires a specific number of Bowden cable kits, One set contains two cables, 2440 mm long, For use with IZMX-MIL...C-F.., IZMX-MIL...C-W.., Bowden cables
Accessories, Bowden cables, The description of the mechanical interlock requires a specific number of Bowden cable kits, One set contains two cables, 1830 mm long, For use with IZMX-MIL...C-F.., IZMX-MIL...C-W.., Bowden cables
Accessories, Bowden cables, The description of the mechanical interlock requires a specific number of Bowden cable kits, One set contains two cables, 1520 mm long, For use with IZMX-MIL...C-F.., IZMX-MIL...C-W.., Bowden cables