Accessories, 2nd shunt release, Only in combination with a zfirstz shunt release., Cannot be combined with an undervoltage release., Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control voltage Us 208 - 240 V AC 50/60 Hz, 208 - 250 V DC V, Operating range x US 0,7 - 1,1 Factor, max. holding current In 0.034 A, max. continuous power AC/DC 9 VA/W, Circuit-breaker total switching time @ US=100% 30 (IZMX16…, INX16…), 35 (IZMX40…, INX40…) ms, For use with IZMX16..., IZMX40..., INX16..., INX40
Accessories, Standard auxiliary switch for On-Off signaling, The basic device already contains two changeover contacts, 2 additionally integrated changeover contacts are included, For use with IZMX16.., IZMX40.., INX16.., INX40.., 2 changeover contacts
Accessories, Standard auxiliary switch for On-Off signaling, The basic device already contains two changeover contacts, 4 additionally integrated changeover contacts are included, For use with IZMX40.., INX40.., 4 changeover contacts
Accessories, Standard auxiliary switch for On-Off signaling, The basic device already contains two changeover contacts, 8 additionally integrated changeover contacts are included, For use with IZMX40.., INX40.., 8 changeover contacts
Accessories, Operational readiness indicator directly connected to spring release, Automatic closing after readiness for operation., Can only be used together with a closing release, For use with IZMX16..., IZMX40..., INX16..., INX40..., 1 changeover contact
Akcesoria, napęd silnika. Silnik automatycznie napina mechanizm magazynowania siły sprężyny w celu zdalnego lub lokalnego uruchamiania. Maksymalna częstotliwość pracy uruchamianie/minutę 3. Uwaga: częstotliwość załączania wyłącznika = 60/h, znamionowe napięcie sterowania Us 220–240 V AC, 50/60 Hz, 220–250...
Akcesoria, napęd silnika. Silnik automatycznie napina mechanizm magazynowania siły sprężyny w celu zdalnego lub lokalnego uruchamiania. Maksymalna częstotliwość pracy uruchamianie/minutę 3. Uwaga: częstotliwość załączania wyłącznika = 60/h, znamionowe napięcie sterowania Us 110–127 V AC, 50/60 Hz, 110–125...
Akcesoria, napęd silnika. Silnik automatycznie napina mechanizm magazynowania siły sprężyny w celu zdalnego lub lokalnego uruchamiania. Maksymalna częstotliwość pracy uruchamianie/minutę 3. Uwaga: częstotliwość załączania wyłącznika = 60/h, znamionowe napięcie sterowania Us 220–240 V AC, 50/60 Hz, 220–250...
Akcesoria, napęd silnika. Silnik automatycznie napina mechanizm magazynowania siły sprężyny w celu zdalnego lub lokalnego uruchamiania. Maksymalna częstotliwość pracy uruchamianie/minutę 3. Uwaga: częstotliwość załączania wyłącznika = 60/h, znamionowe napięcie sterowania Us 24 V DC V, zakres roboczy...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h...
Accessories, Shunt release (for power circuit breaker), Can be combined with an undervoltage release or a second shunt release., Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h...
Accessories, 2nd shunt release, Only in combination with a zfirstz shunt release., Cannot be combined with an undervoltage release., Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency =...
Accessories, Undervoltage release, Cannot be combined with a second shunt release., Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control voltage Us 208 - 240 V AC 50/60...
Accessories, Undervoltage release, Cannot be combined with a second shunt release., Maximum operating frequency Actuations/minute 3, Limited to 3/min due to the high pick-up current for 35 ms., Please note - the circuit-breaker"s switching frequency = 60/h, Rated control voltage Us 24 V DC V, Operating...
Akcesoria, blokowanie przycisków WŁ./WYŁ., przyciski WŁ./WYŁ. wyłącznika można zablokować za pomocą blokady. Możliwe jest również zablokowanie tylko przycisku ZAŁ lub WYŁ za pomocą kłódki. Oznacza to, że lokalne uruchomienie wyłącznika nie będzie już możliwe. Opcjonalny mechanizm zdalnego przełączania...
Akcesoria, Standardowy przełącznik pomocniczy do sygnalizacji wł.–wył, Urządzenie podstawowe zawiera już dwa zestyki przełączne., Zestaw montażowy z 2 dodatkowymi zestykami przełącznymi z kablem o długości do IZMX16., Do zastosowania z IZMX16..., INX16..., 2 zestyki przełączne
Akcesoria, Standardowy przełącznik pomocniczy do sygnalizacji wł.–wył, Urządzenie podstawowe zawiera już dwa zestyki przełączne., Zestaw montażowy z 2 dodatkowymi zestykami przełącznymi z kablem o długości do IZMX40., Do zastosowania z IZMX40..., INX40..., 2 zestyki przełączne