TeSys GV extended rotary handle, for motor circuit breakers GV3L, GV3P mounted inside an enclosure and to be operated externally. For main switch usage, it provides a black handle on grey front plate with indication of 3 positions OFF, ON, TRIP. To be mounted on the door of the enclosure, the handle...
TeSys GV auxiliary contact block, 1NO fault signalling contact and 1NO instantaneous auxiliary contact, for motor circuit breakers GV2 and GV3. Instantaneous auxiliary contact rated for AC operation up to 6A/690V and DC operation up to 6A/240V DC, fault signalling contact rated for AC operation up to...
TeSys GV auxiliary contact block, instantaneous auxiliary contacts 1NO+1NC, for motor circuit breakers GV2 and GV3. For AC operation up to 2A/240V and DC operation up to 1A/60V DC. To be installed on front side of the circuit breaker, 1 block mounting maximum, connection by screw clamp terminals. Sold...
TeSys GV electrical trip, MX shunt release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of...
TeSys GV electrical trip, MX shunt release, 220-240V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker...
Wyzwalacz elektryczny TeSys GV, wyzwalacz wzrostowy MX, 380-400V AC 50Hz / 440V AC 60Hz, do wyłączników silnikowych GV2, GV3. Wyzwala wyłącznik, gdy napięcie sterujące jest podawane w granicach 0,7-1,1 Uc z czasem trwania impulsu większym niż 20 ms lub utrzymywanym sygnałem. Do montażu po...
TeSys GV electrical trip, MN undervoltage release, 24V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in...
TeSys GV electrical trip, MN undervoltage release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage...
TeSys GV electrical trip, MN undervoltage release, 200V AC 50Hz / 200-220V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage...
Wyzwalacz elektryczny TeSys GV, wyzwalacz podnapięciowy MN, 220-240V AC 60Hz, do wyłączników silnikowych GV2, GV3. Wyzwala wyłącznik, gdy napięcie sterujące spadnie poniżej 0,35 Uc, możliwe otwarcie w zakresie 0,35-0,7 Uc. Zamknięcie wyłącznika jest możliwe tylko wtedy, gdy napięcie sterujące...
Wyłącznik elektryczny TeSys GV, wyłącznik podnapięciowy MN, 415-440 V AC 50 Hz / 480 V AC 60 Hz, do wyłączników silnikowych GV2, GV3. Wyłącza wyłącznik automatyczny, gdy napięcie sterujące spadnie poniżej 0.35 Uc, możliwe otwarcie między 0.35-0.7 Uc. Zamknięcie wyłącznika jest możliwe...